Indexed by:
Abstract:
This paper presents the test results of fire-exposed concrete-filled steel tubular (CFST) beam columns repaired by unidirectional carbon fibre reinforced polymer (CFRP) composites. Both circular and square specimens were tested to investigate the repair effects of CFRP composites on them. The test results showed that tile load-bearing capacity of the fire-exposed CFST beam columns was enhanced by tile CFRP jackets to some extent, while the influence of CFRP repair on stiffness was not apparent. The strength enhancement from CFRP confinement decreased with the increasing of eccentricity or slenderness ratio. Ductility enhancement was also observed except those axially loaded shorter specimens with rupture of CFRP jackets at the mid-height, occurred near tile peak loads. However, tile strengths of all repaired specimens have not been fully restored due to the long exposure time of them in fire. From the test results, it is recommended that, in repairing severely fire-damaged CFST members, slender members or those members subjected to comparatively large bending moments, other appropriate repair measures should be taken. (c) 2006 Elsevier Ltd. All rights reserved.
Keyword:
Reprint 's Address:
Email:
Version:
Source :
THIN-WALLED STRUCTURES
ISSN: 0263-8231
Year: 2007
Issue: 1
Volume: 45
Page: 63-76
0 . 5 5 2
JCR@2007
5 . 7 0 0
JCR@2023
ESI Discipline: ENGINEERING;
JCR Journal Grade:2
Cited Count:
WoS CC Cited Count: 99
SCOPUS Cited Count: 115
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 2
Affiliated Colleges: