Indexed by:
Abstract:
The ability of phenols to quench the chemiluminescence of p-chlorobenzenediazonium fluoroborate in a medium of alkaline hydrogen peroxide was studied, and a now injection chemiluminescent quench method for the determination of volatile phenols in polluted water was established, The linear calibration ranges are 0-6.0, 0-5.0, 0-4.5 and 0-8.0 mu g ml(-1) and the detection limits are 0.015, 0.020, 0.025 and 0.030 mu g ml(-1) for phenol, o-nitrophenol, p-cresol and 2,4-xylenol, respectively, This method is more sensitive than the 4-aminoantipyrine direct spectrophotometric method and the flow injection spectrophotometric method, The relative standard deviation is 3.0% for 1 mu g ml(-1) phenol.
Keyword:
Reprint 's Address:
Email:
Version:
Source :
The Analyst
ISSN: 0003-2654
Year: 1995
Issue: 1
Volume: 120
Page: 121-124
3 . 6 0 0
JCR@2023
ESI Discipline: CHEMISTRY;
Cited Count:
WoS CC Cited Count: 19
SCOPUS Cited Count: 18
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 0
Affiliated Colleges: