Static tests were conducted on integral structure of light steel temporary buildings under wind load. The mechanical behavior and the deformation performance of the structure were investigated. A kind of new system of load distribution beams was applied, which imposed the horizontal loads and simulated the uniformly distributed wind load. The load-displacement curves of the columns were obtained. And the strains of the columns and the wall panels were obtained also. The performances of the light steel temporary building are summarized and discussed.