With the development of force metrology within super-large range,force transfer system with a super-large range has become a hotspot in the field of force metrology recent years. An uncertainty calculation model of the build-up system with a super-large rangeconsidering the influence of the build-up structure was developed. A 60 MN build-up system was calibrated and its uncertainty was evaluated and verified. The researchresultsshow that the deformation of the build-up structure would induce indication error in the build-up system. The uncertainty component induced by the indication error is larger than that induced by the force transducer,whichis the main component in the combined uncertainty of build-up system with a super-large range. In the evaluation, the influence of this component should be fully considered; when extrapolating the indication error and its uncertainty to full range, the power function should be used to perform the curve fitting and extrapolation of the build-up system indication error and its uncertainty, which will guarantee thatthe extrapolation results are accurate and reliable. © 2019, Science Press. All right reserved.