• Complex
  • Title
  • Keyword
  • Abstract
  • Scholars
  • Journal
  • ISSN
  • Conference
成果搜索

author:

Tang, Dianping (Tang, Dianping.) [1] | Hou, Li (Hou, Li.) [2] | Niessner, Reinhard (Niessner, Reinhard.) [3] | Xu, Mingdi (Xu, Mingdi.) [4] | Gao, Zhuangqiang (Gao, Zhuangqiang.) [5] | Knopp, Dietmar (Knopp, Dietmar.) [6]

Indexed by:

EI

Abstract:

A novel multiplexed stripping voltammetric immunoassay protocol was designed for the simultaneous detection of multiple biomarkers (CA 125, CA 15-3, and CA 19-9 used as models) using PAMAM dendrimer-metal sulfide quantum dot (QD) nanolabels as distinguishable signal tags and trifunctionalized magnetic beads as an immunosensing probe. The probe was prepared by means of co-immobilization of primary monoclonal anti-CA 125, anti-CA 15-3 and anti-CA 19-9 antibodies on a single magnetic bead. The PAMAM dendrimer-metal sulfide QD nanolabels containing CdS, ZnS and PbS were synthesized by using in situ synthesis method, which were utilized for the labeling of polyclonal rabbit anti-CA 125, anti-CA 15-3 and anti-CA 19-9 detection antibodies, respectively. A sandwich-type immunoassay format was adopted for the simultaneous determination of target biomarkers in a low-binding microtiter plate. The subsequent anodic stripping voltammetric analysis of cadmium, zinc, and lead components released by acid from the corresponding QD nanolabels was conducted at an in situ prepared mercury film electrode based on the difference of peak potentials. Experimental results indicated that the multiplexed immunoassay enabled the simultaneous detection of three cancer biomarkers in a single run with wide dynamic ranges of 0.01-50UmL-1 and detection limits (LODs) of 0.005UmL-1. Intra-assay and inter-assay coefficients of variation (CVs) were less than 7.2% and 10.4%, respectively. No significant differences at the 0.05 significance level were encountered in the analysis of 10 clinical serum specimens between the multiplexed immunoassay and a commercially available enzyme-linked immunosorbent assay (ELISA). © 2013 Elsevier B.V.

Keyword:

Antibodies Biomarkers Cadmium sulfide Chemical detection Dendrimers Diseases II-VI semiconductors Immunology IV-VI semiconductors Lead compounds Magnetism Metals Nanocrystals Probes Semiconductor quantum dots Sulfur compounds Zinc sulfide

Community:

  • [ 1 ] [Tang, Dianping]Key Laboratory of Analysis and Detection for Food Safety, Fujian Province and Ministry of Education, Department of Chemistry, Fuzhou University, Fuzhou 350166, China
  • [ 2 ] [Hou, Li]Key Laboratory of Analysis and Detection for Food Safety, Fujian Province and Ministry of Education, Department of Chemistry, Fuzhou University, Fuzhou 350166, China
  • [ 3 ] [Niessner, Reinhard]Institute of Hydrochemistry, Technische Universität München, Marchioninistrasse 17, D-81377 München, Germany
  • [ 4 ] [Xu, Mingdi]Key Laboratory of Analysis and Detection for Food Safety, Fujian Province and Ministry of Education, Department of Chemistry, Fuzhou University, Fuzhou 350166, China
  • [ 5 ] [Gao, Zhuangqiang]Key Laboratory of Analysis and Detection for Food Safety, Fujian Province and Ministry of Education, Department of Chemistry, Fuzhou University, Fuzhou 350166, China
  • [ 6 ] [Knopp, Dietmar]Institute of Hydrochemistry, Technische Universität München, Marchioninistrasse 17, D-81377 München, Germany

Reprint 's Address:

Show more details

Related Keywords:

Source :

Biosensors and Bioelectronics

ISSN: 0956-5663

Year: 2013

Volume: 46

Page: 37-43

6 . 4 5 1

JCR@2013

1 0 . 7 0 0

JCR@2023

JCR Journal Grade:1

CAS Journal Grade:1

Cited Count:

WoS CC Cited Count:

SCOPUS Cited Count: 118

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 0

Affiliated Colleges:

Online/Total:111/10040468
Address:FZU Library(No.2 Xuyuan Road, Fuzhou, Fujian, PRC Post Code:350116) Contact Us:0591-22865326
Copyright:FZU Library Technical Support:Beijing Aegean Software Co., Ltd. 闽ICP备05005463号-1