Indexed by:
Abstract:
Based on the softened truss model for reinforced concrete, a simplified calculation method is proposed to simulate the whole loading process of high strength reinforced concrete panels. The calculated results of eight panels using the method are in good agreement with the available test data. The new method is simpler than other methods, since it is accomplished from stress evaluation to strain evaluation. The new method can be used in designing the reinforced high strength concrete panels and in checking the resistant capacity of high strength reinforced concrete panels.
Keyword:
Reprint 's Address:
Email:
Version:
Source :
Engineering Mechanics
ISSN: 1000-4750
CN: 11-2595/O3
Year: 2003
Issue: 3
Volume: 20
Page: 38-41,46
Cited Count:
SCOPUS Cited Count:
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 1
Affiliated Colleges: