Indexed by:
Abstract:
The shaking table tests are conducted on a 5-floor steel frame model with a scale down of 1:6. The traditional anti-seismic structure and isolation structures with isolation layer in different position are adopted. The results indicate that the natural vibration periods of isolation structure are longer than anti-seismic structure, and when the isolation layer is located in a lower position, the period becomes longer and the damping effect is better. © (2014) Trans Tech Publications, Switzerland.
Keyword:
Reprint 's Address:
Email:
Source :
ISSN: 1660-9336
Year: 2014
Volume: 580-583
Page: 1776-1781
Language: English
Cited Count:
SCOPUS Cited Count: 1
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 0
Affiliated Colleges: