• Complex
  • Title
  • Keyword
  • Abstract
  • Scholars
  • Journal
  • ISSN
  • Conference
成果搜索

author:

Li, Xiao Jing (Li, Xiao Jing.) [1] | Tang, Xi (Tang, Xi.) [2] | Zhou, Xue Hui (Zhou, Xue Hui.) [3] | Chen, Min Shi (Chen, Min Shi.) [4] | Dai, Jin Lan (Dai, Jin Lan.) [5] | Xiong, Wen Ming (Xiong, Wen Ming.) [6] | Zou, Zhe Xiang (Zou, Zhe Xiang.) [7] | Liu, Hua Jian (Liu, Hua Jian.) [8] | Lv, Shui Yuan (Lv, Shui Yuan.) [9] | Lin, Hua (Lin, Hua.) [10] | Lian, Ming (Lian, Ming.) [11]

Indexed by:

EI

Abstract:

A method based on reversed-phase liquid chromatography-tandem mass spectrometry (LC/MS/MS) combined with solid phase extraction (SPE) was developed and validated for qualitative and quantitative detection of eight parabens in three types of water-based food stimulants including distilled water, 3% acetic acid, 10% alcohol. Detection limits of eight parabens after SPE procedure were 0.005-0.010 μg/L in distilled water, 0.006-0.015 μg/L in 3% acetic acid and 0.005-0.017 μg/L in 10% alcohol. The relative standard deviations (RSDs) were in the range of 1.90-8.48% for distilled wsater, 1.01-3.73% for 3% acetic acid and 5.78-12.97% for 10% alcohol. The method could make a complement for detecting parabens migrated to food and feeds. © (2013) Trans Tech Publications, Switzerland.

Keyword:

Acetic acid Liquid chromatography Mass spectrometry Parabens pH

Community:

  • [ 1 ] [Li, Xiao Jing]Technical Centre of Fujian Entry-Exit Inspection and Quarantine Bureau, Fuzhou 350001, China
  • [ 2 ] [Tang, Xi]Technical Centre of Fujian Entry-Exit Inspection and Quarantine Bureau, Fuzhou 350001, China
  • [ 3 ] [Zhou, Xue Hui]Technical Centre of Fujian Entry-Exit Inspection and Quarantine Bureau, Fuzhou 350001, China
  • [ 4 ] [Chen, Min Shi]Technical Centre of Fujian Entry-Exit Inspection and Quarantine Bureau, Fuzhou 350001, China
  • [ 5 ] [Dai, Jin Lan]Technical Centre of Fujian Entry-Exit Inspection and Quarantine Bureau, Fuzhou 350001, China
  • [ 6 ] [Xiong, Wen Ming]MOE Key Laboratory of Analysis and Detection for Food Safety, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian, 350002, China
  • [ 7 ] [Zou, Zhe Xiang]Technical Centre of Fujian Entry-Exit Inspection and Quarantine Bureau, Fuzhou 350001, China
  • [ 8 ] [Liu, Hua Jian]Technical Centre of Fujian Entry-Exit Inspection and Quarantine Bureau, Fuzhou 350001, China
  • [ 9 ] [Lv, Shui Yuan]Technical Centre of Fujian Entry-Exit Inspection and Quarantine Bureau, Fuzhou 350001, China
  • [ 10 ] [Lin, Hua]Technical Centre of Fujian Entry-Exit Inspection and Quarantine Bureau, Fuzhou 350001, China
  • [ 11 ] [Lian, Ming]Technical Centre of Fujian Entry-Exit Inspection and Quarantine Bureau, Fuzhou 350001, China

Reprint 's Address:

Email:

Show more details

Related Keywords:

Source :

ISSN: 1660-9336

Year: 2013

Volume: 333-335

Page: 1993-1997

Language: English

Cited Count:

WoS CC Cited Count:

SCOPUS Cited Count: 2

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 2

Affiliated Colleges:

Online/Total:209/10053540
Address:FZU Library(No.2 Xuyuan Road, Fuzhou, Fujian, PRC Post Code:350116) Contact Us:0591-22865326