Indexed by:
Abstract:
A new flow injection chemiluminescent method has been developed for the determination of procaine hydrochloride, based on the inhibition of the chemiluminescence reaction of luminol-hydrogen peroxide by procaine hydrochloride. The influence of several surfactants and β-cyclodextrin on the chemiluminescence intensity were studied. It was found that β-cyclodextrin enhanced the decrease in chemiluminescence intensity. The method is simple, convenient and sensitive, with a detection limit (3 σ) of 0.08 μg/mL. The decreased chemiluminescence intensity is linear, with the concentration of procaine hydrochloride in the range 0.2-100.0 μg/mL and 100.0-400.0 μg/mL. The relative standard deviation for 10 repeated measurements were 4.5% and 3.4% for 1.0 and 20.0 μg/mL procaine hydrochloride, respectively. The method has been successfully applied to the determination of procaine hydrochloride in injection solutions of this drug. Copyright © 2003 John Wiley & Sons, Ltd.
Keyword:
Reprint 's Address:
Email:
Source :
Luminescence
ISSN: 1522-7235
Year: 2003
Issue: 3
Volume: 18
Page: 125-130
1 . 6 4 9
JCR@2003
3 . 2 0 0
JCR@2023
JCR Journal Grade:3
Cited Count:
SCOPUS Cited Count: 20
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 0
Affiliated Colleges: