• Complex
  • Title
  • Keyword
  • Abstract
  • Scholars
  • Journal
  • ISSN
  • Conference
成果搜索

author:

Li, R. (Li, R..) [1] | Wang, C. (Wang, C..) [2] | Hu, Y. (Hu, Y..) [3] | Zheng, O. (Zheng, O..) [4] | Guo, L. (Guo, L..) [5] | Lin, Z. (Lin, Z..) [6] | Qiu, B. (Qiu, B..) [7] | Chen, G. (Chen, G..) [8]

Indexed by:

Scopus

Abstract:

Owning to the characteristics such as high sensitivity and simplicity of apparatus, electrochemiluminescence (ECL) has become a powerful analytical technique and has been widely used. Ru(phen)3 2+ can be intercalated into the grooves of dsDNA and act as an ECL probe efficiently, which has been applied to develop a sensitive ECL biosensor for folate receptor in this study. One ssDNA with a thiol group at its 3' termini had been modified on the Au electrode first, and the other ssDNA with folic acid at its 3' termini hybridized with the former one being modified on the electrode surface to form a dsDNA. In the absence of folate receptor, the 3'-terminus in the dsDNA region can be specificity hydrolyzed into mononucleotides by ExoIII and on dsDNA presents on the electrode surface, leading to the lower of ECL intensity detected. However, in the presence of the target (folate receptor), ExoIII failed to hydrolyze the dsDNA since the one 3'-terminus had been protected by the target and the other protected by the Au electrode, resulting in the enhancement of ECL intensity. The enhanced ECL intensity has a linear relationship with the logarithm of folate receptor concentration in the range of 0.66nmol/L and 26.31nmol/L with a detection limit of 0.1204nmol/L. The proposed biosensor had been applied to detect HeLa cells concentration with satisfied results. © 2014 Elsevier B.V.

Keyword:

Biosensor; Electrochemiluminescence; Folate receptor; Terminal protection

Community:

  • [ 1 ] [Li, R.]MOE Key Laboratory of Analysis and Detection for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian 350108, China
  • [ 2 ] [Li, R.]Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian 350108, China
  • [ 3 ] [Wang, C.]MOE Key Laboratory of Analysis and Detection for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian 350108, China
  • [ 4 ] [Wang, C.]Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian 350108, China
  • [ 5 ] [Hu, Y.]MOE Key Laboratory of Analysis and Detection for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian 350108, China
  • [ 6 ] [Hu, Y.]Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian 350108, China
  • [ 7 ] [Zheng, O.]MOE Key Laboratory of Analysis and Detection for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian 350108, China
  • [ 8 ] [Zheng, O.]Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian 350108, China
  • [ 9 ] [Guo, L.]MOE Key Laboratory of Analysis and Detection for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian 350108, China
  • [ 10 ] [Guo, L.]Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian 350108, China
  • [ 11 ] [Lin, Z.]MOE Key Laboratory of Analysis and Detection for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian 350108, China
  • [ 12 ] [Lin, Z.]Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian 350108, China
  • [ 13 ] [Qiu, B.]MOE Key Laboratory of Analysis and Detection for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian 350108, China
  • [ 14 ] [Qiu, B.]Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian 350108, China
  • [ 15 ] [Chen, G.]MOE Key Laboratory of Analysis and Detection for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian 350108, China
  • [ 16 ] [Chen, G.]Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian 350108, China

Reprint 's Address:

  • [Zheng, O.]MOE Key Laboratory of Analysis and Detection for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian 350108, China

Show more details

Related Keywords:

Related Article:

Source :

Biosensors and Bioelectronics

ISSN: 0956-5663

Year: 2014

Volume: 58

Page: 226-231

6 . 4 0 9

JCR@2014

1 0 . 7 0 0

JCR@2023

ESI HC Threshold:268

JCR Journal Grade:1

CAS Journal Grade:1

Cited Count:

WoS CC Cited Count:

SCOPUS Cited Count:

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 1

Affiliated Colleges:

Online/Total:261/10015756
Address:FZU Library(No.2 Xuyuan Road, Fuzhou, Fujian, PRC Post Code:350116) Contact Us:0591-22865326
Copyright:FZU Library Technical Support:Beijing Aegean Software Co., Ltd. 闽ICP备05005463号-1