Indexed by:
Abstract:
In the measurement of nonlinear power capacitor, large DC (direct current) voltage and small AC (alternate current) sinusoidal voltage connected in series are applied to the nonlinear capacitor. In this situation, measurement precision of the capacitor AC sinusoidal voltage and current are critical to the accurate calculation of nonlinear capacitance parameter. Owing to the voltage level diversity, voltage regulation circuit is needed between the measurement terminals and measurement instrument. Though deliberately designed, measurement circuit introduced amplitude and phase error is inevitable. In this paper, an accurate AC sinusoidal small signal measurement method is proposed to promote the measurement precision. The small signal model of the voltage regulation circuit is deduced first. The amplitude and phase angle of the measured sinusoidal small signal is calculated by software phase lock loop (SPLL) method, after which the amplitude and phase angle error is compensated based on the deduced small signal model of the voltage regulation and filter measuring circuit and frequency response method. The correctness and effectiveness of the proposed accurate AC sinusoidal small signal measurement method has been verified by simulation experiment. © 2024 SPIE.
Keyword:
Reprint 's Address:
Email:
Version:
Source :
ISSN: 0277-786X
Year: 2024
Volume: 13211
Language: English
Cited Count:
SCOPUS Cited Count:
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 4
Affiliated Colleges: