author:

Tang, Shurong (Tang, Shurong.) [1] | Tong, Ping (Tong, Ping.) [2] | Li, Heng (Li, Heng.) [3] | Tang, Jing (Tang, Jing.) [4] | Zhang, Lan (Zhang, Lan.) [5]

Indexed by:

EI

Abstract:

A novel highly sensitive and selective electrochemical sensing system based on DNAzyme and rolling circle amplification (RCA) for the determination of Pb2+ was developed in the present study. Firstly, the DNAzyme catalytic strands were immobilized onto magnetic beads surface and then hybridized with substrate strands. In the presence of Pb2+, the DNAzyme could be activated to cleave the substrate strand into two DNA fragments. After RCA reaction, a long ssDNA product with repeating sequence was obtained. Subsequently, CdS QDs modified ssDNA (CdS QD-ssDNA) were used as signaling probes to hybridize with the long ssDNA product. Due to the dramatic signal amplification by the numerous QDs and the low background signal by magnetic separation, ultra-low level (7.8pM) of Pb2+ could be detected. Furthermore, with the application of Pb2+ dependent DNAzyme, the proposed sensing system exhibited high selectivity. The proposed sensing system showed a promising potential for on-site testing and would gain wide applications in real sample analysis. © 2012 Elsevier B.V.

Keyword:

Amplification Cadmium sulfide Chemical detection Electrochemical sensors II-VI semiconductors Magnetic separation Nanocrystals Semiconductor quantum dots

Community:

  • [ 1 ] [Tang, Shurong]Ministry of Education Key Laboratory of Analysis and Detection for Food Safety, Fujian Provincial Key Laboratory of Analysis and Detection for Food Safety, College of Chemistry and Chemical Engineering, Fuzhou University, Fuzhou, Fujian 350108, China
  • [ 2 ] [Tong, Ping]Ministry of Education Key Laboratory of Analysis and Detection for Food Safety, Fujian Provincial Key Laboratory of Analysis and Detection for Food Safety, College of Chemistry and Chemical Engineering, Fuzhou University, Fuzhou, Fujian 350108, China
  • [ 3 ] [Tong, Ping]Analytical and Testing Center, The Sport Science Research Center, Fuzhou University, Fuzhou, Fujian 350002, China
  • [ 4 ] [Li, Heng]Ministry of Education Key Laboratory of Analysis and Detection for Food Safety, Fujian Provincial Key Laboratory of Analysis and Detection for Food Safety, College of Chemistry and Chemical Engineering, Fuzhou University, Fuzhou, Fujian 350108, China
  • [ 5 ] [Tang, Jing]Ministry of Education Key Laboratory of Analysis and Detection for Food Safety, Fujian Provincial Key Laboratory of Analysis and Detection for Food Safety, College of Chemistry and Chemical Engineering, Fuzhou University, Fuzhou, Fujian 350108, China
  • [ 6 ] [Zhang, Lan]Ministry of Education Key Laboratory of Analysis and Detection for Food Safety, Fujian Provincial Key Laboratory of Analysis and Detection for Food Safety, College of Chemistry and Chemical Engineering, Fuzhou University, Fuzhou, Fujian 350108, China
  • [ 7 ] [Zhang, Lan]Analytical and Testing Center, The Sport Science Research Center, Fuzhou University, Fuzhou, Fujian 350002, China

Reprint 's Address:

Show more details

Related Keywords:

Source :

Biosensors and Bioelectronics

ISSN: 0956-5663

Year: 2013

Issue: 1

Volume: 42

Page: 608-611

6 . 4 5 1

JCR@2013

1 0 . 7 0 0

JCR@2023

JCR Journal Grade:1

CAS Journal Grade:1

Cited Count:

WoS CC Cited Count:

SCOPUS Cited Count: 103

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 3

Affiliated Colleges:

Online/Total:411/10034319
Address:FZU Library(No.2 Xuyuan Road, Fuzhou, Fujian, PRC Post Code:350116) Contact Us:0591-22865326