Indexed by:
Abstract:
This paper briefly introduces the pulse transformer and its main technical indicators, analyzes the influence of parasitic parameters on the output waveform of the pulse transformer from the time domain, and obtains the values of delay time, overshoot voltage and top-drop, which provides reference for the design of the pulse transformer. A pulse transformer with smaller leakage inductance and parasitic capacitance is proposed, which can have faster response speed. © 2022 IEEE.
Keyword:
Reprint 's Address:
Email:
Source :
Year: 2022
Page: 1486-1491
Language: English
Cited Count:
SCOPUS Cited Count:
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 1
Affiliated Colleges: