Abstract:

A total of 16 concrete-filled high-strength steel tube specimens were designed to evaluate the effects of shear-to-span ratio and concrete strength on the shear behavior of concrete-filled high-strength steel tube specimens. The failure mode and shear-displacement curve of the specimens were obtained through the test, and the effects of shear-to-span ratio, core concrete strength, and other parameters on the failure mode, shear-displacement curve, shear-shear strain curve, shear strength, and shear stiffness were compared. The results show that similar to conventional concrete-filled steel tube specimens, the shear-to-span ratio is the key parameter controlling the failure mode of the concrete-filled high-strength steel tube specimens. When the shear-to-span ratio is 0.2 or 0.5, shear failure occurs; when the shear-to-span ratio is 0.8 or 1.0, shear-flexural failure occurs. By implementing ultra-high performance concrete (UHPC), the deformation capacity of the concrete-filled high-strength steel tube specimens (with a shear-to-span ratio of 1.0) is reduced by 61.4%. However, shear strength and stiffness increase by 38.9% and 85.7%, respectively. Additionally, local buckling of the steel tubes is effectively delayed, and the damage degree of the specimens is reduced. The inclination angle of the main diagonal cracks in the core concrete decreases with an increase in the shear-to-span ratio but is not affected by the concrete strength. The average value of tested shear strength/calculated shear strength (Vexp/Vu) is 0.97, with a deviation of 0.03, showing higher accuracy and smaller dispersion. It is considered that the formula can accurately predict the shear strength of concrete-filled high-strength steel tubes. © 2025 Science Press. All rights reserved.

Keyword:

concrete-filled steel tube design method failure mode high-strength steel tube shear behavior

Community:

  • [ 1 ] [Wang J.]College of Civil Engineering, Fuzhou University, Fuzhou, 350000, China
  • [ 2 ] [Wang Y.]College of Civil Engineering, Fuzhou University, Fuzhou, 350000, China
  • [ 3 ] [Chen X.]College of Civil Engineering, Fuzhou University, Fuzhou, 350000, China
  • [ 4 ] [Yang D.]College of Civil Engineering, Fuzhou University, Fuzhou, 350000, China
  • [ 5 ] [Lai Z.]College of Civil Engineering, Fuzhou University, Fuzhou, 350000, China

Reprint 's Address:

Email:

Show more details

Related Keywords:

Source :

Journal of Southwest Jiaotong University

ISSN: 0258-2724

Year: 2025

Issue: 3

Volume: 60

Page: 628-638

Cited Count:

WoS CC Cited Count:

SCOPUS Cited Count:

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 3

Affiliated Colleges:

Online/Total:1486/13841982
Address:FZU Library(No.2 Xuyuan Road, Fuzhou, Fujian, PRC Post Code:350116) Contact Us:0591-22865326
Copyright:FZU Library Technical Support:Beijing Aegean Software Co., Ltd. 闽ICP备05005463号-1