Indexed by:
Abstract:
A novel flow injection chemiluminescence method has been developed for the determination of doxycycline(DC) based on the inhibition of chemiluminescence reaction of Luminol-KMnO4 by using DC in sodium hydroxide medium. Using different concentrations of KMnO4, a series of good linear regression equations of decreased chemiluminescence intensity and the concentration of DC were obtained with different subsections in the concentration range of 0.005-5.0 mug(.)mL(-1). The detection limit (3sigma) is 2.0 X 10(-3) mug(.)mL(-1). The method has been successfully applied to the determination of DC in a Pharmaceutical preparation.
Keyword:
Reprint 's Address:
Email:
Source :
SPECTROSCOPY AND SPECTRAL ANALYSIS
ISSN: 1000-0593
CN: 11-2200/O4
Year: 2004
Issue: 1
Volume: 24
Page: 15-17
0 . 3 5
JCR@2004
0 . 7 0 0
JCR@2023
ESI Discipline: CHEMISTRY;
JCR Journal Grade:4
Cited Count:
WoS CC Cited Count: 9
SCOPUS Cited Count:
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 0