Abstract:

Electrochemical point-of-care testing (POCT) technology is widely used in clinical testing, health management, epidemic control, food safety monitoring, and drug detection. Existing electrochemical POCT devices are mostly single-channel tests with a simple detection index, fixed sensitivity, and limited test range. In this article, a dual-channel, high-precision electrochemical device with automatic analytic software is developed. Two independent channels with consistent performance can be operated at the same time, multiplying the detection efficiency. The digital potentiometer is adopted as the feedback resistor for the operational amplifier, and an automatic adjustment program is set up on the smartphone app to achieve automatic adjustment of current detection sensitivity. An automatic peak-seeking function is proposed, which can quickly locate and record the peak voltage and current. The current detection range from +/- 10 nA to & PLUSMN;2 mA with a sensitivity up to 10(-8)A and a current detection resolution as low as 0.062% (6.19 pA in the +/- 10 nA range) are obtained. The device has been carried out for the simultaneous detection of ascorbic acid (AA), uric acid (UA), and dopamine (DA) (R-2 > 0.977). The results indicate that the dual-channel device is of wide linear detection range, high precision, and consistency. It provides a technical means and a test platform for accurate and timely diagnosis of relevant diseases and health monitoring.

Keyword:

Automatic range adjustment dual channel electrochemical detection Electrodes high current detection sensitivity Performance evaluation point-of-care testing (POCT) Resistors Sensitivity Sensors smartphone Software Workstations

Community:

  • [ 1 ] [Wei, Yi]Fuzhou Univ, Coll Phys & Informat Engn, Fuzhou 350108, Peoples R China
  • [ 2 ] [Zhang, Xiaotao]Fuzhou Univ, Coll Phys & Informat Engn, Fuzhou 350108, Peoples R China
  • [ 3 ] [Chen, Xing]Fuzhou Univ, Coll Phys & Informat Engn, Fuzhou 350108, Peoples R China
  • [ 4 ] [Gao, Yueming]Fuzhou Univ, Coll Phys & Informat Engn, Fuzhou 350108, Peoples R China
  • [ 5 ] [Pan, Haibo]Fuzhou Univ, Coll Chem, Fuzhou 350108, Peoples R China
  • [ 6 ] [Vasic, Z. Lucev]Univ Zagreb, Fac Elect Engn & Comp, Zagreb 10000, Croatia
  • [ 7 ] [Cifrek, Mario]Univ Zagreb, Fac Elect Engn & Comp, Zagreb 10000, Croatia

Reprint 's Address:

Show more details

Related Keywords:

Source :

IEEE SENSORS JOURNAL

ISSN: 1530-437X

Year: 2023

Issue: 4

Volume: 23

Page: 3699-3709

4 . 3

JCR@2023

4 . 3 0 0

JCR@2023

ESI Discipline: ENGINEERING;

ESI HC Threshold:35

JCR Journal Grade:1

CAS Journal Grade:2

Cited Count:

WoS CC Cited Count: 0

SCOPUS Cited Count: 1

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 0

Online/Total:239/10043492
Address:FZU Library(No.2 Xuyuan Road, Fuzhou, Fujian, PRC Post Code:350116) Contact Us:0591-22865326
Copyright:FZU Library Technical Support:Beijing Aegean Software Co., Ltd. 闽ICP备05005463号-1