Abstract:

MEKC was used in conjunction with end-column amperometric detection (AD) at a carbon disc electrode (0.3 mm diameter) for the selective and sensitive determination of melatonin and its five related indoleamines including its precursors and metabolites in the pineal gland. The introduction of a sample stacking technique in injection and the buffer additive SIDS in the buffer solution system provided the rapid and sensitive analysis. Optimal buffer conditions (10 mmol/L phosphate containing 20 mmol/L SIDS, pH 7.2), detection potential (+1.0 V vs. Ag/AgCl), and electrokinetic injection 10 s with the separation voltage of 24 kV were employed to achieve the baseline separation of six pineal hormones within 15 min. The peak currents and the analyte concentrations have a good linear relationship over the range of 6.0 x 10(-8)similar to 6.0 x 10(-5) mol/L. The detection limits for six pineal hormones by AD are 9.7 to 41.8 nmol/L (equal to 2.0 to 9.7 ng/mL) (S/N = 3), respectively. It is proved to provide about 30- to 250-fold improvement over UV, and be comparable with the sensitive fluorescence detection, which needs pre-column derivatization. The proposed method has been applied for analysis of melatonin and related indoleamines in rat pineal glands. A very simple sample pretreatment procedure, merely involving the homogenization step in perchloric acid, was enough to achieve recoveries in the range of 71 to 127% for all the analytes in the pineal gland.

Keyword:

end-column amperometric detection MEKC melatonin and related indoleamines pineal hormones

Community:

  • [ 1 ] Fuzhou Univ, Dept Chem, Minist Educ, Key Lab Anal & Detect Technol Food Safety, Fuzhou 350002, Fujian, Peoples R China

Reprint 's Address:

  • 陈国南

    [Chen, Guonan]Fuzhou Univ, Dept Chem, Minist Educ, Key Lab Anal & Detect Technol Food Safety, Fuzhou 350002, Fujian, Peoples R China

Show more details

Related Keywords:

Source :

ELECTROPHORESIS

ISSN: 0173-0835

Year: 2006

Issue: 21

Volume: 27

Page: 4230-4239

4 . 1 0 1

JCR@2006

3 . 0 0 0

JCR@2023

ESI Discipline: CHEMISTRY;

JCR Journal Grade:1

Cited Count:

WoS CC Cited Count: 14

SCOPUS Cited Count:

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 0

Online/Total:202/10039244
Address:FZU Library(No.2 Xuyuan Road, Fuzhou, Fujian, PRC Post Code:350116) Contact Us:0591-22865326
Copyright:FZU Library Technical Support:Beijing Aegean Software Co., Ltd. 闽ICP备05005463号-1